富二代国产app

您好!歡迎光臨冷水機源頭廠家,我們竭誠為您服務!
熱門關健詞:
?

長春市制冷設備附屬件及管道安裝方法

2023-12-13

1、長春市(shi)制冷輔(fu)助(zhu)設備:冷凝器(qi)、蒸發器(qi)、儲液(ye)器(qi)、油分離氣體(ti)、汽液(ye)分離器(qi)、過濾器(qi)

1. 檢(jian)查各設備(bei)的噴(pen)頭方(fang)向和位置(zhi)是否符(fu)合設計要(yao)求;

2. 應進行氣密性試驗和單體吹制(zhi)(R22根據使用(yong)的(de)制(zhi)冷劑不同,試驗壓(ya)(ya)力值在高(gao)壓(ya)(ya)側為(wei)2.0~2.5mpa,低(di)壓(ya)(ya)側為(wei)1.8MPa);

3.水(shui)平設備水(shui)平安裝(zhuang)偏差(cha)為1‰;

因為(wei)冷水機(ji)組具(ju)有非常好(hao)的(de)工作特(te)性,在使用(yong)(yong)效果(guo)(guo)(guo)上會(hui)更(geng)(geng)加規范(fan)。當然,它會(hui)在相對自然的(de)環境中*為(wei)使用(yong)(yong),能夠充分發揮(hui)使用(yong)(yong)壽命長(chang)的(de)特(te)點。如果(guo)(guo)(guo)想讓(rang)(rang)其應用(yong)(yong)實踐(jian)效果(guo)(guo)(guo)顯得更(geng)(geng)強,也可以(yi)考慮大家的(de)應用(yong)(yong)規則,就需要選擇合適的(de)效果(guo)(guo)(guo)類型(xing)標準,這樣才(cai)能讓(rang)(rang)使用(yong)(yong)實踐(jian)效果(guo)(guo)(guo)更(geng)(geng)加**。

4. 集油(you)器(出(chu)油(you)口)應稍低;

5. 低(di)溫側設(she)備(bei)與其他(ta)設(she)備(bei)接(jie)觸時,襯墊厚度不(bu)得小于保溫層厚度;

6. 與(yu)設備連接的管道(dao)的方向和位置應(ying)符合工(gong)藝(yi)流程和設計要求。

2、制(zhi)冷系統(tong)管路的安裝

長(chang)春市制冷系(xi)統管(guan)道安裝前,應先清除(chu)管(guan)道內(nei)的氧化皮、污染物和鐵(tie)銹,待內(nei)壁表面有(you)光澤后才能將管(guan)道兩(liang)端(duan)封閉。

制冷設備

3、與(yu)液(ye)管(guan)連(lian)接的支管(guan)應從總(zong)管(guan)底部或側面連(lian)接

與(yu)燃氣管(guan)連(lian)接的支管(guan)應從上部或(huo)側部連(lian)接。供液(ye)管(guan)不得有(you)凸(tu)彎,吸入管(guan)除特(te)別設置回油彎外(wai),不得有(you)凹(ao)彎。

4、設備間制冷劑(ji)管路(lu)連接的坡度(du)方向和(he)坡度(du):

壓(ya)縮(suo)機(ji)進口水平管道坡度(du)至(zhi)壓(ya)縮(suo)機(ji)坡度(du):≥1%;

制冷機

壓縮機排氣水平管到油分離器的斜(xie)率:≥1%;

在保證設備安全運行的情況下,制冷主機運行在70%-80%負載比運行在****負載時,單位冷量的功耗更小。運用此方式開機要結合水泵、冷卻塔的運行情況綜合考慮。
4.采用制冷機(ji)(ji)變(bian)(bian)頻裝(zhuang)置,調(diao)節離(li)心制冷機(ji)(ji)壓(ya)(ya)縮(suo)機(ji)(ji)的轉(zhuan)速(su)(su)低壓(ya)(ya)的冷媒經過離(li)心機(ji)(ji)后,壓(ya)(ya)力升(sheng)(sheng)高。離(li)心機(ji)(ji)的轉(zhuan)速(su)(su)越(yue)大,壓(ya)(ya)力升(sheng)(sheng)得越(yue)高。在實(shi)際運行中,設備大多是在非滿(man)負(fu)荷(he)運行。固定轉(zhuan)速(su)(su)的離(li)心機(ji)(ji)在設備小負(fu)荷(he)運行時,造成能源浪費。而變(bian)(bian)頻離(li)心制冷機(ji)(ji)可以依據負(fu)荷(he)的變(bian)(bian)化,自動(dong)調(diao)節壓(ya)(ya)縮(suo)機(ji)(ji)轉(zhuan)速(su)(su),節能空(kong)間比較大。

冷凝器(qi)(qi)到(dao)蒸發器(qi)(qi)到(dao)蒸發器(qi)(qi)的(de)水(shui)平管(guan)斜率(lv):1~3‰;

1、膨脹閥、過濾器、高低壓表、電磁閥等冷凍元件及電氣件均采用美國、臺灣及日本名牌,精密度高故障率低,使用壽命長。
2、采用臺灣微電腦溫控器,能**控制水溫于+3℃到+45℃內。
3.所有控制均設于冷水機正面,只需按下開關,調至所需溫度,便能自動操作,簡便快捷。
4.采用馬來西亞進口**率銅管,特別設(she)計(ji)制(zhi)作冷(leng)凝器(qi)(qi)及蒸發器(qi)(qi),散(san)熱量大,體積小巧,大大增強冷(leng)水機(ji)的冷(leng)凍效(xiao)能。

制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)可(ke)分(fen)為(wei)(wei):壓縮式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)、吸收(shou)式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)、蒸(zheng)汽(qi)(qi)噴射式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji),半導體制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)。其(qi)中蒸(zheng)汽(qi)(qi)壓縮式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)(活塞式(shi)(shi)(shi)(shi)(shi)(shi)、回轉式(shi)(shi)(shi)(shi)(shi)(shi)、螺(luo)桿式(shi)(shi)(shi)(shi)(shi)(shi)、離(li)(li)心式(shi)(shi)(shi)(shi)(shi)(shi))、吸收(shou)式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)和(he)蒸(zheng)汽(qi)(qi)噴射式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji)應用較為(wei)(wei)廣泛。我(wo)國除少數大冷(leng)(leng)(leng)(leng)(leng)(leng)量和(he)特(te)殊用途(tu)的冷(leng)(leng)(leng)(leng)(leng)(leng)凍機(ji)(ji)(ji)外,一般用途(tu)的活塞式(shi)(shi)(shi)(shi)(shi)(shi)、離(li)(li)心式(shi)(shi)(shi)(shi)(shi)(shi)、螺(luo)桿式(shi)(shi)(shi)(shi)(shi)(shi)、渦旋式(shi)(shi)(shi)(shi)(shi)(shi) 、溴化鋰吸收(shou)式(shi)(shi)(shi)(shi)(shi)(shi)、蒸(zheng)汽(qi)(qi)噴射式(shi)(shi)(shi)(shi)(shi)(shi)制(zhi)冷(leng)(leng)(leng)(leng)(leng)(leng)機(ji)(ji)(ji),以及(ji)冷(leng)(leng)(leng)(leng)(leng)(leng)凍、冷(leng)(leng)(leng)(leng)(leng)(leng)藏、低(di)溫試驗等設備都能(neng)自己(ji)制(zhi)造

從油分(fen)離器(qi)到(dao)冷凝器(qi)再(zai)到(dao)油分(fen)離器(qi)的(de)水(shui)平管(guan)坡度(du):3~5‰;

5、預防措施

1. 設備(bei)、管道的保溫(wen)材料、保溫(wen)范圍和厚度應(ying)滿足設計要求(qiu)。

2. 管道上的所有閥門都(dou)應進(jin)行一次(ci)氣密性試驗。

3.閥(fa)門及(ji)附件的安(an)裝應符合下列要求:

(1)單向閥(fa)應按制(zhi)冷劑(ji)流動方向安(an)裝(zhuang);

激光冷凍機

反應釜冷水機

電鍍冷水機

冷水機制冷形式:冷水機的性能形式,大致可分為二種,風冷式冷水機-特點:1.免裝冷卻塔,安裝容易,移動方便,適合于水源缺乏免裝水塔場合。2.低噪音風機馬達,**的冷卻冷凝效果,穩定節流機構,優異的防銹處理。
3.采用歐美進口高性能壓縮機,高EER值,噪音低,運行穩。
水冷式冷水機-特點
1.人體工學面板,全自動化控制,配備精密電溫控制器,可長期平穩運行。
2.采用**傳熱換熱器,冷量損失少,易回油,傳熱管不致發生凍裂優點。
3.采(cai)用(yong)日美進口高性能壓縮機,高EER值(zhi),噪聲低,運行穩

(2)對于帶手柄(bing)(bing)的(de)閥門(men),手柄(bing)(bing)不得向下;

(3)電磁閥(fa)、熱(re)膨脹閥(fa)、升降(jiang)式止(zhi)回閥(fa)等的(de)閥(fa)頭(tou)應垂(chui)直向上安裝;

(4)熱(re)膨脹閥的安裝(zhuang)位(wei)置應靠(kao)近蒸發器,以便進(jin)行(xing)調整和維護;感溫(wen)包(bao)的安裝(zhuang)應符(fu)合要求。